Hardware Configuration
|
Item |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
Processors per controller |
1 x 4-core processor |
|
|
|
|
|
Cache size per controller |
|
|
|
|
|
|
Maximum number of controllers per enclosure |
2 |
4 |
|||
|
Maximum number of IP scale-out controllers |
8 |
||||
|
Maximum number of disks |
500 |
750 |
1200 |
1500 |
3200 |
|
Controller enclosure configuration |
|
3 U controller enclosure without disks |
6 U controller enclosure without disks |
||
|
Supported disk enclosure types |
|
||||
|
Maximum number of disk enclosures |
|
|
|
|
|
|
Maximum number of disk enclosures connected to back-end channels (ports) |
|
||||
|
Supported disk types |
SSD, SAS, and NL-SAS |
||||
|
Supported hot-swappable interface module types |
|
||||
|
Supported hot-swappable expansion module type |
12 Gbit/s SAS |
||||
|
Maximum number of hot-swappable I/O interface modules per controller |
2 |
8 |
6 |
||
|
Length of expansion SAS cables |
Common disk enclosure
High-density disk enclosure
|
||||
|
Redundancy of main components |
|
|
|
|
|
|
a: Each front-end or nodes-interconnection module has four ports. The port types can be 8 Gbit/s Fibre Channel, 10 Gbit/s FCoE (VN2VF), 16 Gbit/s Fibre Channel, 10 Gbit/s Eth (optical port, not negotiable to GE), and iWARP (the RDMA protocol is used for interconnection among scale-out nodes). |
|||||
Port Specifications
|
Maximum Number of Ports per Interface Module |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
8 Gbit/s Fibre Channel interface module (four ports) |
Four ports for each front-end module |
||||
|
8 Gbit/s Fibre Channel interface module (eight ports) |
Eight ports for each front-end module |
||||
|
16 Gbit/s Fibre Channel interface module |
Two ports for each front-end module |
||||
|
GE electrical interface module |
Four ports for each front-end module |
||||
|
10GE electrical interface module |
Four ports for each front-end module |
||||
|
10 Gbit/s FCoE interface module (two ports) |
Two ports for each front-end module |
||||
|
10 Gbit/s FCoE interface module (four ports) |
Four ports for each front-end module |
||||
|
12 Gbit/s SAS expansion module |
Four ports for each back-end module |
||||
|
56 Gbit/s (4 x 14 Gbit/s) IB interface module |
Two ports for each front-end module (The module is used for SAN services only and cannot be used for NAS services. It supports electrical ports only.) |
||||
|
SmartIO interface module |
Four ports per module for each front-end or nodes-interconnection modulea |
||||
|
a: Each front-end or nodes-interconnection module has four ports. The port types can be 8 Gbit/s Fibre Channel, 10 Gbit/s FCoE (VN2VF), 16 Gbit/s Fibre Channel, 10 Gbit/s Eth (optical port, not negotiable to GE), and iWARP (the RDMA protocol is used for interconnection among scale-out nodes). |
|||||
|
Maximum Number of Ports per Controller |
5300 V3a |
5500 V3b |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
8 Gbit/s Fibre Channel port |
16c |
20d |
36 |
28 |
|
|
16 Gbit/s Fibre Channel port |
8 |
12f |
28e |
20e |
|
|
GE port |
12 |
8 |
28 |
20 |
|
|
10GE port |
8 |
8 |
28 |
20 |
|
|
10 Gbit/s FCoE port (VN2VF) |
8 |
28g |
20g |
||
|
10 Gbit/s FCoE port (VN2VN) |
4 |
14 |
10 |
||
|
12 Gbit/s SAS expansion port |
6 |
24 |
16 |
||
|
56 Gbit/s (4 x 14 Gbit/s) IB port |
4 |
14 |
10 |
||
|
a: Onboard front-end ports of the 5300 V3 are GE ports. b: Onboard front-end ports of the 5500 V3 are SmartIO ports. c: The number of ports can reach the upper limit when 8 Gbit/s Fibre Channel high-density interface modules are configured. d: The number of ports can reach the upper limit when 8 Gbit/s Fibre Channel high-density interface modules are configured and 8 Gbit/s Fibre Channel optical modules are configured for onboard SmartIO ports. e: The number of ports can reach the upper limit when 16 Gbit/s Fibre Channel optical modules are configured for SmartIO interface modules. f: The number of ports can reach the upper limit when 16 Gbit/s Fibre Channel optical modules are configured for SmartIO interface modules and onboard SmartIO ports. g: The number of ports can reach the upper limit when 10 Gbit/s FCoE interface modules (4 ports) are configured or 10 Gbit/s FCoE optical modules are configured for SmartIO interface modules. |
|||||
Disk Specifications
|
Disk Typea |
Dimensions |
Rotational Speed |
Weight |
Capacity |
|---|---|---|---|---|
|
SAS |
2.5-inch |
10,000 rpm |
0.25 kg (0.55 lb) |
|
|
15,000 rpm |
0.25 kg (0.55 lb) |
|
||
|
NL-SAS |
3.5-inch |
7200 rpm |
0.725 kg (1.60 lb) |
|
|
SSD |
2.5-inch |
– |
0.25 kg (0.55 lb) |
|
|
3.5-inch |
0.35 kg (0.77 lb) |
|||
|
a: Restricted by the storage principles, SSDs and mechanical disks such as NL-SAS and SAS disks cannot be preserved for a long term while they are powered off.
b: Self-encrypting drives (SEDs) are supported. c: High-density disk enclosures are supported. d: SEDs and high-density disk enclosures are supported. e: 2.5-inch disks are supported. |
||||
Dimensions and Weight (Unpackaged)
|
Module |
Parameter |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|---|
|
Controller enclosure |
Dimensions |
|
|
|
||
|
Weight (without disks) |
33 kg (72.75 lb) |
57.5 kg (126.77 lb) |
77 kg (169.76 lb, dual controllers) 92.9 kg (204.81 lb, four controllers) |
|||
|
2 U SAS disk enclosure |
Dimensions |
|
||||
|
Weight (without disks) |
17.5 kg (38.58 lb) |
|||||
|
4 U SAS disk enclosure |
Dimensions |
|
||||
|
Weight (without disks) |
26.5 kg (58.43 lb) |
|||||
|
4 U high-density disk enclosure |
Dimensions |
Cable managers not included:
Cable managers included:
|
||||
|
Weight (without disks) |
50.5 kg (111.33 lb) |
|||||
|
Item |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|
|---|---|---|---|---|---|---|
|
Power consumption |
Controller enclosure |
|
|
|
|
|
|
2 U disk enclosure |
|
|||||
|
4 U disk enclosure |
|
|||||
|
4 U high-density disk enclosure |
|
|||||
|
Power voltage and rated current |
Controller enclosure |
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
|||
|
Disk enclosure |
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
||||
|
High-density disk enclosure |
AC:
|
|||||
|
AC power input type (socket type) |
|
|||||
|
Each BBU capacity |
18 Wh |
38.5 Wh |
38.5 Wh |
38.5 Wh |
||
|
a: dual controllers b: four controllers NOTE:
|
||||||
|
Item |
Value |
|---|---|
|
Solution reliability |
99.9999% |
|
Mean Time Between Failures (MTBF) |
1,000,000 hours |
|
Mean Time To Repair (MTTR) |
2 hours |
Related models
Frequently asked questions
Are drives and expansion shelves included?
Controllers, drives, shelves and licenses are quoted as separate line items so you only pay for what you need. Tell us the target capacity and we build the configuration.
Is firmware and licensing included?
Firmware level and any required license are confirmed on the quotation, because they depend on the release your environment runs.
Is the system tested before dispatch?
Every unit is powered on, firmware-checked and burn-in tested before dispatch. Test logs or photos can be shared on request.
Can you confirm controller model, firmware level and condition before I order?
Yes. Before the order we send the controller model, firmware level, drive list and condition for your written confirmation.
How are warranty and lead time handled?
Warranty, firmware support period and lead time are confirmed on the quotation, since they follow the controller and drive mix you choose.
Xinchuan Server | Enterprise Server Hardware Supplier