Hardware Configuration
|
Item
|
Value
|
|
Processors per controller
|
1 x 16-core processor
|
|
Cache size per controller
|
|
|
Maximum number of controllers per enclosure
|
2
|
|
Maximum number of IP Scale-out controllers
|
2
|
|
Maximum number of disks
|
300
|
|
Controller enclosure configuration
|
- 2 U controller enclosure with twenty-five 2.5-inch disks
- 2 U controller enclosure with twelve 3.5-inch disks
|
|
Supported disk enclosure types
|
- 2 U SAS disk enclosure with twenty-five 2.5-inch disks
- 4 U SAS disk enclosure with twenty-four 3.5-inch disks
|
|
Maximum number of disk enclosures
|
13
|
|
Maximum number of disk enclosures that can be connected to back-end channels (ports)
|
Up to eight disk enclosures can be connected a SAS expansion port. Two are recommended.
|
|
Supported disk types
|
SSD, SAS, NL-SAS
|
|
Supported hot-swappable interface module types
|
- 8 Gbit/s Fibre Channel
- GE
- 10GE (electrical)
- 2-port SmartIOa
- 4-port SmartIOb
|
|
Maximum number of hot-swappable I/O interface modules per controller
|
- For versions earlier than V300R006C20: 1
- For V300R006C20 and later versions: 2
|
|
Length of expansion SAS cables
|
Controller enclosure
- Electrical cables: 1 m, 2 m, and 3 m
Disk enclosure
- Electrical cables: 1 m, 2 m, 3 m, and 5 m
- Optical cable: 15 m
|
|
Redundancy degree of main components
|
- Backup power module: 1 (per controller)
- Power modules: 1+1
- Fans: 1+1
|
|
a: SmartIO interface modules support various ports including 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports.
b: SmartIO interface modules support various ports including 8 Gbit/s Fibre Channel ports, 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports (optical port, not negotiable to GE), and iWARP (interconnection between Scale-out nodes).
|
|
Interface Module Type
|
Maximum Number of Ports per Interface Module
|
|
8-port 8 Gbit/s Fibre Channel interface module
|
Eight ports for each front-end module
|
|
GE electrical interface module
|
Four ports for each front-end module
|
|
10GE electrical interface module
|
Four ports for each front-end module
|
|
2-port SmartIO interface module
|
Two ports for each front-end modulea
|
|
4-port SmartIO interface module
|
Four ports per module for each front-end or nodes-interconnection moduleb
|
|
a: SmartIO interface modules support various ports including 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports.
b: SmartIO interface modules support various ports including 8 Gbit/s Fibre Channel ports, 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports (optical port, not negotiable to GE), and iWARP (interconnection between Scale-out nodes).
|
|
Port Type
|
Max. Number of Ports per Controller
|
|
8 Gbit/s Fibre Channel port
|
16
|
|
16 Gbit/s Fibre Channel port
|
8
|
|
GE porta
|
14b
|
|
10GE port
|
8
|
|
10 Gbit/s FCoE port (VN2VF)
|
8
|
|
12 Gbit/s SAS expansion portc
|
2
|
|
a: Onboard front-end ports of the 2200 V3 are GE ports.
b: includes two ports that can function as maintenance and service network ports, four onboard front-end ports, and eight hot-swappable front-end ports.
c: functions as the onboard back-end port.
|
|
Disk Typea
|
Dimensions
|
Rotational Speed
|
Weight
|
Capacity
|
|
SAS
|
2.5-inch
|
10,000 rpm
|
0.25 kg (0.55 lb)
|
- 600 GBb
- 900 GB
- 1.2 TBb
- 1.8 TBb
- 2.4 TB
|
|
15,000 rpm
|
0.25 kg (0.55 lb)
|
600 GB
|
|
NL-SAS
|
3.5-inch
|
7200 rpm
|
0.725 kg (1.60 lb)
|
- 2 TB
- 4 TBb
- 6 TBb
- 8 TB
- 10 TBb
- 12 TB
|
|
SSD
|
2.5-inch
|
–
|
0.25 kg (0.55 lb)
|
- 600 GB
- 900 GBb
- 960 GBb
- 1.8 TBb
- 1.92 TBb
- 3.6 TBb
- 3.84 TBb
- 7.2 TB
- 7.68 TBd
- 15.36 TBc
- 30.72 TB
|
|
3.5-inch
|
0.35 kg (0.77 lb)
|
|
a: Restricted by the storage principles, SSDs and mechanical disks such as NL-SAS and SAS disks cannot be preserved for a long term while they are powered off.
- When the ambient temperature is lower than 40ºC, SSDs where no data is stored can be preserved for a maximum of 12 months while they are powered off, and SSDs where data has been stored can be preserved for a maximum of 3 months while they are powered off. If the maximum preservation time is exceeded, data loss or SSD failure may occur.
- When the wet-bulb temperature is lower than 30ºC, packed mechanical disks and unpacked mechanical disks that are powered off can be preserved for a maximum of six months. If the maximum preservation time is exceeded, data loss or disk failure may occur. The maximum preservation time is determined based on the disk preservation specifications provided by the mechanical disk vendor. For details about the specifications, see the manual provided by the vendor.
b: Self-encrypting disks (not sold in the Chinese mainland) are supported.
c: 2.5-inch disks are supported.
d: Self-encrypting disks (not sold in the Chinese mainland) and 2.5-inch disks are supported.
|
|
Module
|
Parameter
|
Value
|
|
Controller enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 86.1 mm (3.39 in.)
|
|
Weight (without disks)
|
15.9 kg (35.05 lb)
|
|
2 U SAS disk enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 86.1 mm (3.39 in.)
|
|
Weight (without disks)
|
13.3 kg (29.32 lb)
|
|
4 U SAS disk enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 175 mm (6.89 in.)
|
|
Weight (without disks)
|
26.5 kg (58.42 lb)
|
|
Item
|
Value
|
|
Power consumption
|
Controller enclosure
|
12 disk slots
- Max: 393 W
- Typical: 305 W
- Min: 284 W
25 disk slots
- Max: 429 W
- Typical: 329 W
- Minimum: 212 W
|
|
2 U disk enclosure
|
- Max: 268 W
- Typical: 215 W
- Minimum: 205 W
|
|
4 U disk enclosure
|
- Max: 472 W
- Typical: 360 W
- Minimum: 340 W
|
|
Power voltage and rated current
|
Controller enclosure
|
- AC: 100 V to 240 V, ±10%, 800 W, 10 A
- High voltage DC (N/A for North America and Canada): 240 V, 800 W, 10 A
|
|
Disk enclosure
|
- AC: 100 V to 240 V, ±10%, 800 W, 10 A
- High voltage DC (N/A for North America and Canada): 240 V, 800 W, 10 A
|
|
AC power input type (socket type)
|
- AC: IEC60320-C14
- High voltage DC: IEC60320-C14
|
|
Power supply by the backup power module
|
600 WS
|
|
Item
|
Value
|
|
Solution reliability
|
99.9999%
|
|
Mean Time Between Failures (MTBF)
|
1,000,000 hours
|
|
Mean Time To Repair (MTTR)
|
2 hours
|
Related models
Frequently asked questions
Are drives and expansion shelves included?
Controllers, drives, shelves and licenses are quoted as separate line items so you only pay for what you need. Tell us the target capacity and we build the configuration.
Is firmware and licensing included?
Firmware level and any required license are confirmed on the quotation, because they depend on the release your environment runs.
Is the system tested before dispatch?
Every unit is powered on, firmware-checked and burn-in tested before dispatch. Test logs or photos can be shared on request.
Can you confirm controller model, firmware level and condition before I order?
Yes. Before the order we send the controller model, firmware level, drive list and condition for your written confirmation.
How are warranty and lead time handled?
Warranty, firmware support period and lead time are confirmed on the quotation, since they follow the controller and drive mix you choose.
Huawei storage parts reference
Hardware Configuration
|
Item
|
Value
|
|
Processors per controller
|
1 x 16-core processor
|
|
Cache size per controller
|
|
|
Maximum number of controllers per enclosure
|
2
|
|
Maximum number of IP Scale-out controllers
|
2
|
|
Maximum number of disks
|
300
|
|
Controller enclosure configuration
|
- 2 U controller enclosure with twenty-five 2.5-inch disks
- 2 U controller enclosure with twelve 3.5-inch disks
|
|
Supported disk enclosure types
|
- 2 U SAS disk enclosure with twenty-five 2.5-inch disks
- 4 U SAS disk enclosure with twenty-four 3.5-inch disks
|
|
Maximum number of disk enclosures
|
13
|
|
Maximum number of disk enclosures that can be connected to back-end channels (ports)
|
Up to eight disk enclosures can be connected a SAS expansion port. Two are recommended.
|
|
Supported disk types
|
SSD, SAS, NL-SAS
|
|
Supported hot-swappable interface module types
|
- 8 Gbit/s Fibre Channel
- GE
- 10GE (electrical)
- 2-port SmartIOa
- 4-port SmartIOb
|
|
Maximum number of hot-swappable I/O interface modules per controller
|
- For versions earlier than V300R006C20: 1
- For V300R006C20 and later versions: 2
|
|
Length of expansion SAS cables
|
Controller enclosure
- Electrical cables: 1 m, 2 m, and 3 m
Disk enclosure
- Electrical cables: 1 m, 2 m, 3 m, and 5 m
- Optical cable: 15 m
|
|
Redundancy degree of main components
|
- Backup power module: 1 (per controller)
- Power modules: 1+1
- Fans: 1+1
|
|
a: SmartIO interface modules support various ports including 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports.
b: SmartIO interface modules support various ports including 8 Gbit/s Fibre Channel ports, 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports (optical port, not negotiable to GE), and iWARP (interconnection between Scale-out nodes).
|
|
Interface Module Type
|
Maximum Number of Ports per Interface Module
|
|
8-port 8 Gbit/s Fibre Channel interface module
|
Eight ports for each front-end module
|
|
GE electrical interface module
|
Four ports for each front-end module
|
|
10GE electrical interface module
|
Four ports for each front-end module
|
|
2-port SmartIO interface module
|
Two ports for each front-end modulea
|
|
4-port SmartIO interface module
|
Four ports per module for each front-end or nodes-interconnection moduleb
|
|
a: SmartIO interface modules support various ports including 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports.
b: SmartIO interface modules support various ports including 8 Gbit/s Fibre Channel ports, 16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports (optical port, not negotiable to GE), and iWARP (interconnection between Scale-out nodes).
|
|
Port Type
|
Max. Number of Ports per Controller
|
|
8 Gbit/s Fibre Channel port
|
16
|
|
16 Gbit/s Fibre Channel port
|
8
|
|
GE porta
|
14b
|
|
10GE port
|
8
|
|
10 Gbit/s FCoE port (VN2VF)
|
8
|
|
12 Gbit/s SAS expansion portc
|
2
|
|
a: Onboard front-end ports of the 2200 V3 are GE ports.
b: includes two ports that can function as maintenance and service network ports, four onboard front-end ports, and eight hot-swappable front-end ports.
c: functions as the onboard back-end port.
|
|
Disk Typea
|
Dimensions
|
Rotational Speed
|
Weight
|
Capacity
|
|
SAS
|
2.5-inch
|
10,000 rpm
|
0.25 kg (0.55 lb)
|
- 600 GBb
- 900 GB
- 1.2 TBb
- 1.8 TBb
- 2.4 TB
|
|
15,000 rpm
|
0.25 kg (0.55 lb)
|
600 GB
|
|
NL-SAS
|
3.5-inch
|
7200 rpm
|
0.725 kg (1.60 lb)
|
- 2 TB
- 4 TBb
- 6 TBb
- 8 TB
- 10 TBb
- 12 TB
|
|
SSD
|
2.5-inch
|
–
|
0.25 kg (0.55 lb)
|
- 600 GB
- 900 GBb
- 960 GBb
- 1.8 TBb
- 1.92 TBb
- 3.6 TBb
- 3.84 TBb
- 7.2 TB
- 7.68 TBd
- 15.36 TBc
- 30.72 TB
|
|
3.5-inch
|
0.35 kg (0.77 lb)
|
|
a: Restricted by the storage principles, SSDs and mechanical disks such as NL-SAS and SAS disks cannot be preserved for a long term while they are powered off.
- When the ambient temperature is lower than 40ºC, SSDs where no data is stored can be preserved for a maximum of 12 months while they are powered off, and SSDs where data has been stored can be preserved for a maximum of 3 months while they are powered off. If the maximum preservation time is exceeded, data loss or SSD failure may occur.
- When the wet-bulb temperature is lower than 30ºC, packed mechanical disks and unpacked mechanical disks that are powered off can be preserved for a maximum of six months. If the maximum preservation time is exceeded, data loss or disk failure may occur. The maximum preservation time is determined based on the disk preservation specifications provided by the mechanical disk vendor. For details about the specifications, see the manual provided by the vendor.
b: Self-encrypting disks (not sold in the Chinese mainland) are supported.
c: 2.5-inch disks are supported.
d: Self-encrypting disks (not sold in the Chinese mainland) and 2.5-inch disks are supported.
|
Dimensions and Weight (Unpacked)
|
Module
|
Parameter
|
Value
|
|
Controller enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 86.1 mm (3.39 in.)
|
|
Weight (without disks)
|
15.9 kg (35.05 lb)
|
|
2 U SAS disk enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 86.1 mm (3.39 in.)
|
|
Weight (without disks)
|
13.3 kg (29.32 lb)
|
|
4 U SAS disk enclosure
|
Dimensions
|
- Depth: 488 mm (19.21 in.)
- Width: 447 mm (17.60 in.)
- Height: 175 mm (6.89 in.)
|
|
Weight (without disks)
|
26.5 kg (58.42 lb)
|
|
Item
|
Value
|
|
Power consumption
|
Controller enclosure
|
12 disk slots
- Max: 393 W
- Typical: 305 W
- Min: 284 W
25 disk slots
- Max: 429 W
- Typical: 329 W
- Minimum: 212 W
|
|
2 U disk enclosure
|
- Max: 268 W
- Typical: 215 W
- Minimum: 205 W
|
|
4 U disk enclosure
|
- Max: 472 W
- Typical: 360 W
- Minimum: 340 W
|
|
Power voltage and rated current
|
Controller enclosure
|
- AC: 100 V to 240 V, ±10%, 800 W, 10 A
- High voltage DC (N/A for North America and Canada): 240 V, 800 W, 10 A
|
|
Disk enclosure
|
- AC: 100 V to 240 V, ±10%, 800 W, 10 A
- High voltage DC (N/A for North America and Canada): 240 V, 800 W, 10 A
|
|
AC power input type (socket type)
|
- AC: IEC60320-C14
- High voltage DC: IEC60320-C14
|
|
Power supply by the backup power module
|
600 WS
|
|
Item
|
Value
|
|
Solution reliability
|
99.9999%
|
|
Mean Time Between Failures (MTBF)
|
1,000,000 hours
|
|
Mean Time To Repair (MTTR)
|
2 hours
|
Huawei storage parts reference