Hardware Configuration
|
Item |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
Processors per controller |
1 x 4-core processor |
|
|
|
|
|
Cache size per controller |
|
|
|
|
|
|
Maximum number of controllers per enclosure |
2 |
4 |
|||
|
Maximum number of IP scale-out controllers |
8 |
||||
|
Maximum number of disks |
500 |
750 |
1200 |
1500 |
3200 |
|
Controller enclosure configuration |
|
3 U controller enclosure without disks |
6 U controller enclosure without disks |
||
|
Supported disk enclosure types |
|
||||
|
Maximum number of disk enclosures |
|
|
|
|
|
|
Maximum number of disk enclosures connected to back-end channels (ports) |
|
||||
|
Supported disk types |
SSD, SAS, and NL-SAS |
||||
|
Supported hot-swappable interface module types |
|
||||
|
Supported hot-swappable expansion module type |
12 Gbit/s SAS |
||||
|
Maximum number of hot-swappable I/O interface modules per controller |
2 |
8 |
6 |
||
|
Length of expansion SAS cables |
Common disk enclosure
High-density disk enclosure
|
||||
|
Redundancy of main components |
|
|
|
|
|
|
a: Each front-end or nodes-interconnection module has four ports. The port types can be 8 Gbit/s Fibre Channel, 10 Gbit/s FCoE (VN2VF), 16 Gbit/s Fibre Channel, 10 Gbit/s Eth (optical port, not negotiable to GE), and iWARP (the RDMA protocol is used for interconnection among scale-out nodes). |
|||||
Port Specifications
|
Maximum Number of Ports per Interface Module |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
8 Gbit/s Fibre Channel interface module (four ports) |
Four ports for each front-end module |
||||
|
8 Gbit/s Fibre Channel interface module (eight ports) |
Eight ports for each front-end module |
||||
|
16 Gbit/s Fibre Channel interface module |
Two ports for each front-end module |
||||
|
GE electrical interface module |
Four ports for each front-end module |
||||
|
10GE electrical interface module |
Four ports for each front-end module |
||||
|
10 Gbit/s FCoE interface module (two ports) |
Two ports for each front-end module |
||||
|
10 Gbit/s FCoE interface module (four ports) |
Four ports for each front-end module |
||||
|
12 Gbit/s SAS expansion module |
Four ports for each back-end module |
||||
|
56 Gbit/s (4 x 14 Gbit/s) IB interface module |
Two ports for each front-end module (The module is used for SAN services only and cannot be used for NAS services. It supports electrical ports only.) |
||||
|
SmartIO interface module |
Four ports per module for each front-end or nodes-interconnection modulea |
||||
|
a: Each front-end or nodes-interconnection module has four ports. The port types can be 8 Gbit/s Fibre Channel, 10 Gbit/s FCoE (VN2VF), 16 Gbit/s Fibre Channel, 10 Gbit/s Eth (optical port, not negotiable to GE), and iWARP (the RDMA protocol is used for interconnection among scale-out nodes). |
|||||
|
Maximum Number of Ports per Controller |
5300 V3a |
5500 V3b |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|
|
8 Gbit/s Fibre Channel port |
16c |
20d |
36 |
28 |
|
|
16 Gbit/s Fibre Channel port |
8 |
12f |
28e |
20e |
|
|
GE port |
12 |
8 |
28 |
20 |
|
|
10GE port |
8 |
8 |
28 |
20 |
|
|
10 Gbit/s FCoE port (VN2VF) |
8 |
28g |
20g |
||
|
10 Gbit/s FCoE port (VN2VN) |
4 |
14 |
10 |
||
|
12 Gbit/s SAS expansion port |
6 |
24 |
16 |
||
|
56 Gbit/s (4 x 14 Gbit/s) IB port |
4 |
14 |
10 |
||
|
a: Onboard front-end ports of the 5300 V3 are GE ports. b: Onboard front-end ports of the 5500 V3 are SmartIO ports. c: The number of ports can reach the upper limit when 8 Gbit/s Fibre Channel high-density interface modules are configured. d: The number of ports can reach the upper limit when 8 Gbit/s Fibre Channel high-density interface modules are configured and 8 Gbit/s Fibre Channel optical modules are configured for onboard SmartIO ports. e: The number of ports can reach the upper limit when 16 Gbit/s Fibre Channel optical modules are configured for SmartIO interface modules. f: The number of ports can reach the upper limit when 16 Gbit/s Fibre Channel optical modules are configured for SmartIO interface modules and onboard SmartIO ports. g: The number of ports can reach the upper limit when 10 Gbit/s FCoE interface modules (4 ports) are configured or 10 Gbit/s FCoE optical modules are configured for SmartIO interface modules. |
|||||
Disk Specifications
|
Disk Typea |
Dimensions |
Rotational Speed |
Weight |
Capacity |
|---|---|---|---|---|
|
SAS |
2.5-inch |
10,000 rpm |
0.25 kg (0.55 lb) |
|
|
15,000 rpm |
0.25 kg (0.55 lb) |
|
||
|
NL-SAS |
3.5-inch |
7200 rpm |
0.725 kg (1.60 lb) |
|
|
SSD |
2.5-inch |
– |
0.25 kg (0.55 lb) |
|
|
3.5-inch |
0.35 kg (0.77 lb) |
|||
|
a: Restricted by the storage principles, SSDs and mechanical disks such as NL-SAS and SAS disks cannot be preserved for a long term while they are powered off.
b: Self-encrypting drives (SEDs) are supported. c: High-density disk enclosures are supported. d: SEDs and high-density disk enclosures are supported. e: 2.5-inch disks are supported. |
||||
Dimensions and Weight (Unpackaged)
|
Module |
Parameter |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|---|---|---|---|---|---|---|
|
Controller enclosure |
Dimensions |
|
|
|
||
|
Weight (without disks) |
33 kg (72.75 lb) |
57.5 kg (126.77 lb) |
77 kg (169.76 lb, dual controllers) 92.9 kg (204.81 lb, four controllers) |
|||
|
2 U SAS disk enclosure |
Dimensions |
|
||||
|
Weight (without disks) |
17.5 kg (38.58 lb) |
|||||
|
4 U SAS disk enclosure |
Dimensions |
|
||||
|
Weight (without disks) |
26.5 kg (58.43 lb) |
|||||
|
4 U high-density disk enclosure |
Dimensions |
Cable managers not included:
Cable managers included:
|
||||
|
Weight (without disks) |
50.5 kg (111.33 lb) |
|||||
|
Item |
5300 V3 |
5500 V3 |
5600 V3 |
5800 V3 |
6800 V3 |
|
|---|---|---|---|---|---|---|
|
Power consumption |
Controller enclosure |
|
|
|
|
|
|
2 U disk enclosure |
|
|||||
|
4 U disk enclosure |
|
|||||
|
4 U high-density disk enclosure |
|
|||||
|
Power voltage and rated current |
Controller enclosure |
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
|||
|
Disk enclosure |
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
AC:
DC:
High voltage DC (N/A for North America and Canada)
|
||||
|
High-density disk enclosure |
AC:
|
|||||
|
AC power input type (socket type) |
|
|||||
|
Each BBU capacity |
18 Wh |
38.5 Wh |
38.5 Wh |
38.5 Wh |
||
|
a: dual controllers b: four controllers NOTE:
|
||||||
|
Item |
Value |
|---|---|
|
Solution reliability |
99.9999% |
|
Mean Time Between Failures (MTBF) |
1,000,000 hours |
|
Mean Time To Repair (MTTR) |
2 hours |
Sell Dell/Xfusion/Huawei server,From China.