회사 뉴스

 

How to Design a VMware vSAN ESA Cluster: Hardware Selection, 네트워킹, 및 용량 계획 2026

The vSAN Cluster That Cost $40,000 Too Much Because Someone Spec’d 100GbE for a 25GbE Workload

vSAN ESA (Express Storage Architecture) requires 25GbE networking minimum. It does not require 100GbE. But walk through any data center with a vSAN deployment and you will find at least one cluster where the networking budget consumed 30 percent more than necessary because the spec was written by someone who confusedminimum” ~와 함께 “recommended” 그리고 “recommended” ~와 함께 “we might need it later.This guide covers the hardware decisions that make or break vSAN ESA TCO — from server selection to NVMe drive count to network switch configuration.

Server Selection: The Golden Ratio of NVMe Bays to Memory Channels

vSAN ESA replaces the disk group model (cache drive + 용량 드라이브) with a storage pool where all NVMe drives contribute to a single distributed datastore. The key hardware constraint is no longer the cache-to-capacity ratio — it is the ratio of NVMe bays to memory channels. Each NVMe drive consumes CPU cycles for I/O processing. A server with 24 NVMe bays and 2x 12-core CPUs will be CPU-bound on storage I/O long before it is capacity-bound. The rule of thumb: 2-3 NVMe drives per physical CPU core for mixed workloads, 3-4 for read-heavy.

섬기는 사람 NVMe Bays Recommended CPU (per node) Max Usable Capacity (RAID 5, 4 Nodes) Best For
Dell R670 (1유, 20x e3.s) 까지 20 E3.S Gen5 2x Xeon 6 (56+ cores total recommended) ~300 TB (20x 7.68TB x 4 nodes, RAID 5) High-density 1U, colocation-optimized
델 R760 (2유, 24x 2.5인치) 까지 24 NVMe U.2 2x Xeon Gold 6448Y (32C each) ~360 TB (24x 7.68TB x 4 nodes, RAID 5) Balanced density and expansion
엑스퓨전 2288H V7 (2유, 25x 2.5인치) 까지 28 NVMe 2x Xeon Gold 6448Y (32C each) ~420 TB (28x 7.68TB x 4 nodes, RAID 5) Maximum storage density in 2U
xFusion 5288 V7 (4유, 44x 3.5인치) 까지 4 NVMe + 44 SAS HDD 2x Xeon Gold 6430 (32C each) NVMe: ~60 TB + HDD: ~700 TB Mixed NVMe + capacity HDD (vSAN OSA-style)

네트워킹: 25GbE Is the Minimum. Here Is When 100GbE Actually Makes Sense.

vSAN ESA requires a minimum of 25GbE networking for the vSAN traffic VMkernel port. The actual bandwidth requirement scales with the number of NVMe drives per node and the write workload intensity:

NVMe Drives per Node Typical Peak vSAN Traffic (per node, write-heavy) Required Network Recommended Adapter
4-8 NVMe ~8-12 Gbps 25나르다 (sufficient) 인텔 E810-XXVDA2 (2x 25GbE, RDMA-capable)
12-16 NVMe ~15-22 Gbps 25나르다 (near saturation on writes) 2x 25GbE (LACP active-active, or vSAN traffic on dedicated 25GbE port)
20-28 NVMe ~25-35 Gbps 100GbE recommended (dual 25GbE aggregated may saturate) Mellanox ConnectX-6 Dx (2x 100GbE) or 2x 25GbE in LACP

For most 4-node clusters with 8-12 NVMe drives per node, dual 25GbE SFP28 adapters with one port dedicated to vSAN traffic and the second port for management and vMotion is the cost-optimal configuration. 100GbE becomes justified at 20+ NVMe drives per node or when the cluster is being designed for future expansion to all-NVMe 28-drive nodes.

Four-Node vSAN ESA Cluster Reference Design

요소 Selection 수량 Estimated Cost (per node)
섬기는 사람 델 R760 (24x 2.5인치 NVMe) 4 nodes $18,000
CPU 2x Xeon Gold 6448Y (32 코어, 250승) 8 CPU (2 per node) $3,100 엑스 8 = $24,800
메모리 512 GB (16엑스 32 GB DDR5-4800, 1DPC) 2 총 TB (64 DIMMS) $2,800 per node
저장 12x Micron 7450 PRO 7.68TB NVMe per node (RAID 5, vSAN policy FTT=1) 48 드라이브 (12 per node) $5,200 per node (drives only)
네트워킹 2x Intel E810-XXVDA2 (25GbE SFP28 per node) 8 어댑터 (2 per node) $400 per adapter
Witness Host 델 R470 (1유, single-socket, 64 GB, 2엑스 480 GB NVMe boot) 1 node $3,500
Switch Dell 파워스위치 S5248F-ON (48x 25GbE + 8x 100GbE) 1 스위치 (shared, 8 ports used for vSAN) $8,000 (allocated cost)
Total (4-node cluster + witness) $133,500

Usable capacity: approximately 184 결핵 (12x 7.68TB x 4 nodes, RAID 5 within vSAN, FTT=1 with RAID 5 삭제 코딩). 성능: ~2.4M read IOPS, ~960K write IOPS aggregate across 4 nodes.

vSAN ESA vs vSAN OSA — The Migration Decision

요인 OSA (Original Storage Architecture) ESA (Express Storage Architecture)
Storage model Disk groups: 1 cache SSD + 1-7 용량 드라이브 Storage pool: all NVMe drives contribute equally
Minimum drives per node 2 (1 은닉처 + 1 용량) 4 NVMe drives per node
RAID within vSAN RAID 1 (mirroring) or RAID 5/6 (삭제 코딩, capacity drives only) RAID 5 per object natively, RAID 6 for FTT=2
Network minimum 10나르다 25나르다
Space efficiency (FTT=1, 4 nodes) RAID 1: 50 percent usable. RAID 5: ~75 percent usable. RAID 5 natively: ~75 percent usable, with inline compression (~1.6:1 typical, 까지 4:1)
Best for new deployments in 2026 Hybrid HDD+SSD, budget-constrained, 10GbE infrastructure All-NVMe, performance-oriented, greenfield deployments

Design Your vSAN Cluster With Xincuan

We configure Dell PowerEdge and xFusion FusionServer servers for vSAN ESA with factory-direct pricing, 3-1년 보증, 그리고 글로벌 배송. Our VMware architects can design a cluster topology, validate hardware compatibility with the VMware HCL, and deliver pre-configured nodes ready for vSAN deployment.

Request a vSAN cluster design consultation

Explore platforms: Dell Servers | xFusion Servers | Enterprise SSDs