계층형 엔터프라이즈 스토리지 아키텍처를 설계하는 방법: NVMe, SAS SSD, 및 SAS HDD 레퍼런스 디자인 - Xinchuan 서버 | 엔터프라이즈 서버 하드웨어 공급업체

회사 뉴스

계층형 엔터프라이즈 스토리지 아키텍처를 설계하는 방법: NVMe, SAS SSD, 및 SAS HDD 레퍼런스 디자인

The Storage Architecture That Saves $70,000 per Rack Without Sacrificing Performance

An all-NVMe storage array delivering 100 TB of usable capacity costs roughly $50,000 in drives alone. A tiered architecture delivering the same 100 TB costs roughly $18,000 in drives while delivering 85-90 percent of the performance for 95 percent of workloads. Across a five-rack deployment, 즉 $180,000 in total savings.

The Three Tiers

Tier 드라이브 유형 Example Model 수량 사용 가능한 용량 비용 (드라이브만)
Tier 0: 은닉처 NVMe PCIe 4.0, 3 DWPD, 3.84결핵 Samsung PM9A3 3.84TB 4 (RAID 10) 7.68 결핵 $2,800
Tier 1: Active Data SAS SSD 12Gb/s, 3 DWPD, 3.84결핵 Kingston DC1500M 3.84TB 8 (RAID 10) 15.36 결핵 $5,600
Tier 2: Bulk Capacity SAS HDD 12Gb/s, 20결핵 도시바 MG10 20TB 12 (RAID 6) 160 사용 가능한 TB $4,800
24 드라이브 183 사용 가능한 TB $13,200

Automated vs Manual Storage Tiering

Approach A: Automated Tiering (ZFS, 저장 공간, vSAN). ZFS with a Special Allocation Class on NVMe, a primary pool on SAS SSDs, and a secondary pool on SAS HDDs. Hot blocks migrate to the fastest tier automatically based on access frequency. No manual management required.

Approach B: Manual Classification. The DBA places the database WAL on NVMe (Tier 0), data files on SAS SSD (Tier 1), and backups on SAS HDD (Tier 2). Better performance predictability, but requires ongoing manual management.

Server Configuration: A Tiered Storage Node

요소 Selection Reason
섬기는 사람 델 R760 (2유, 24x 2.5인치) Sufficient bays for all three tiers
Alternative (higher density) 엑스퓨전 2288H V7 (25x 2.5인치, 28 NVMe) More NVMe bays for larger Tier 0 은닉처
CPU 2x 제온 골드 6448Y (32 코어) Filesystem operations. No GPU needed.
메모리 256 GB (16엑스 16 GB DDR5, 1DPC) ZFS ARC: 128 GB for metadata and hot block caching
RAID/HBA 분 H965i (16-포트 Gen5 트라이 모드) Single controller for NVMe, SAS SSD, and SAS HDD
네트워킹 2x 25GbE SFP28 (front-end), 2x 100GbE (back-end) 25GbE for client access, 100GbE for replication
운영체제 TrueNAS Scale or RHEL 9 with ZFS ZFS for tiering. TrueNAS for appliance experience.

Performance Estimates: 183 TB Tiered Storage

작업량 Expected Performance vs All-NVMe
4K 무작위 읽기 (Tier 0 은닉처) ~850K IOPS, 80 us latency 92 percent of all-NVMe
4K 무작위 읽기 (Tier 1 active data) ~95K IOPS, 120 us latency Consistent SAS SSD performance
4K 무작위 읽기 (Tier 2 콜드 데이터) ~150 IOPS, 4ms latency Sequential prefetch mitigates random penalty
순차적 쓰기 (to NVMe cache) ~3.5 GB/s (4x NVMe RAID 10) Writes on NVMe, async destage to slower tiers

Three Deployment Scenarios

1. VMware 데이터스토어 (50 VMS, mixed workloads). NVMe cache absorbs 80 percent of reads. SAS SSD handles active VMDKs. SAS HDD stores snapshots and templates. VMware admins experience NVMe-like latency with 60 percent lower storage cost.

2. PostgreSQL Database (2 결핵, write-heavy OLTP). WAL on NVMe (Tier 0, 미러링된). Data files on SAS SSD (RAID 10). Backups on SAS HDD (RAID 6). WAL writes at 2 GB/s sustained, data reads at 95K IOPS.

3. Media Post-Production NAS (50 TB active, 150 TB archive). Current projects on SAS SSD. Completed archives on SAS HDD. NVMe cache for metadata and small-file I/O.

Design Your Tiered Storage With Xincuan

We supply all three storage tiers with factory-direct pricing, 3-1년 보증, 그리고 글로벌 배송. Our storage architects can design a tiered deployment for your workload.

Request a tiered storage design consultation

Storage products: SSD | HDD | Storage Solutions

이전:

다음:

핸드폰

링크드인 링크드인

스카이프

왓츠앱

위챗 QR 코드 위챗

이메일

위챗

WeChat QR Code

WeChat으로 QR 코드 스캔