Supermicro AOC-SLG3-2M2 | Doppia scheda adattatore PCIe M.2 NVMe - Server Xinchuan | Fornitore di hardware per server aziendali

MAGAZZINAGGIO/

Supermicro AOC-SLG3-2M2 | Doppia scheda adattatore PCIe M.2 NVMe

That Empty PCIe Slot in Your Server Could Hold 15.36 TB of NVMe Storage. Here Is How.Every Dell, xFusione, and Lenovo server has at least one PCIe slot that is not being used for a GPU, NIC, or RAID controller. The Supermicro AOC-SLG3-2M2 turns that empty slot into two additional M.2 NVMe drive bays — adding up to 30.72 TB of NVMe storage to any server without consuming a front-panel drive bay, without a U.2 backplane, and without a single SAS cable.This is the cheapest, simplest path to adding NVMe storage to a server that was not ordered with enough NVMe bays. Populate it with 2x 7.68 TB M.2 22110 azionamenti, and your virtualization host gains an additional 13.8 tubercolosi…

  • Dettagli del prodotto

That Empty PCIe Slot in Your Server Could Hold 15.36 TB of NVMe Storage. Here Is How.

Every Dell, xFusione, and Lenovo server has at least one PCIe slot that is not being used for a GPU, NIC, or RAID controller. The Supermicro AOC-SLG3-2M2 turns that empty slot into two additional M.2 NVMe drive bays — adding up to 30.72 TB of NVMe storage to any server without consuming a front-panel drive bay, without a U.2 backplane, and without a single SAS cable.

This is the cheapest, simplest path to adding NVMe storage to a server that was not ordered with enough NVMe bays. Populate it with 2x 7.68 TB M.2 22110 azionamenti, and your virtualization host gains an additional 13.8 TB of RAID 1 (O 15.36 TB JBOD) storage that lives entirely inside the PCIe slot.

Specifiche tecniche

Parametro Specifica
Modello Supermicro AOC-SLG3-2M2 (PCIe 3.0 variant)
Host Interface PCIe 3.0 x8 (64 Gb/s — sufficient for 2x NVMe Gen3 drives at ~3.5 GB/s each)
Drive Interface 2x M.2 M-key (Nvme, PCIe 3.0 x4 per slot)
Supported M.2 Form Factors 2242, 2260, 2280, 22110 (adjustable standoffs)
Supporto RAID No hardware RAID. RAID software (mdadm, ZFS, Storage Spaces) or VROC (Intel Virtual RAID on CPU) via platform
Bifurcation Required Yes — host PCIe slot must support x4/x4 bifurcation. Most servers from 2020+ support this in BIOS.
Drive Hot-Swap Not supported (internal card — requires opening chassis to replace drives)
LED Indicators Activity LED per drive (green), fault detection
Power to M.2 Slots 3.3v, supplied via PCIe slot (no supplemental power connector needed)
Fattore di forma Low-profile PCIe, staffa a tutta altezza inclusa
Dimensioni fisiche 167 X 69 mm (scheda LP standard)
Raffreddamento Passive (requires chassis airflow across M.2 drives)
Supporto del sistema operativo VMware ESXi 7.0+, 8.0+ | WindowsServer 2019/2022/2025 | RHEL8.6+/9.x | Ubuntu 20.04/22.04/24.04 | TrueNAS Scale | Proxmox VE
Compatible Servers Any server with PCIe 3.0 x8+ slot and x4/x4 bifurcation support
Garanzia 3-anno limitato (produttore)

Five Practical Deployments for the AOC-SLG3-2M2

Deployment Unità Configuration Result
ESXi Boot + Scratch 2X 240 GB M.2 NVMe RAID 1 (software, via ESXi installer) Reliable boot volume, frees 2 front bays for data storage
Hyper-V Storage Spaces 2X 3.84 TB M.2 NVMe Mirror (Storage Spaces) 3.84 TB mirrored VM storage on one PCIe card
TrueNAS SLOG / L2ARC 1X 480 GB M.2 (SLOG) + 1X 1.92 TB M.2 (L2ARC) Dedicated ZFS devices 10x write latency improvement (SLOG), 5x read cache hit rate (L2ARC)
Docker Persistent Volume 2X 7.68 TB M.2 NVMe RAID 1 (mdadm, hardware agnostic) 7.68 TB mirrored container storage in a single PCIe slot
Proxmox Ceph OSD 2X 1.92 TB M.2 NVMe Ceph OSD (bluestore), 1 drive per OSD 2x OSDs per PCIe card — high IOPS density for Ceph clusters

Bifurcation Check — Before You Order

The AOC-SLG3-2M2 requires the host PCIe slot to support x4/x4 bifurcation — splitting the 8 PCIe lanes from the slot into two independent groups of 4 lanes each, one per M.2 drive. Check your server’s BIOS underPCIe Bifurcation” O “Slot Bifurcationsettings. Most Dell PowerEdge 15th/16th Gen, xFusion V7, and Lenovo V3/V4 servers support this on at least one riser slot. If the BIOS shows “x8” soltanto (no bifurcation option), only one M.2 drive will be detected.

On Dell iDRAC9: navigate to Configuration > BIOS Settings > Integrated Devices > Slot Bifurcation. On xFusion iBMC: navigate to BIOS > Advanced > PCI Subsystem > Slot Bifurcation.

Fonte attraverso Xincuan

We supply AOC-SLG3-2M2 adapters pre-installed in server configurations with M.2 drives populated. Prezzi diretti in fabbrica, 3-anno di garanzia, e spedizioni globali.

Request an M.2 adapter configured server quote

Prec:

Prossimo:

lascia un commento

Telefono

Linkedin Linkedin

Skype

WhatsApp

Codice QR WeChat WeChat

E-mail

WeChat

WeChat QR Code

Scansiona il codice QR con WeChat