% % %

ARMAZENAR/

 

Supermicro AOC-SLG3-2M2 | Dual M.2 NVMe PCIe Adapter Card

That Empty PCIe Slot in Your Server Could Hold 15.36 TB of NVMe Storage. Here Is How.Every Dell, xFusion, and Lenovo server has at least one PCIe slot that is not being used for a GPU, Placa de rede, or RAID controller. The Supermicro AOC-SLG3-2M2 turns that empty slot into two additional M.2 NVMe drive bays — adding up to 30.72 TB of NVMe storage to any server without consuming a front-panel drive bay, without a U.2 backplane, and without a single SAS cable.This is the cheapest, simplest path to adding NVMe storage to a server that was not ordered with enough NVMe bays. Populate it with 2x 7.68 TB M.2 22110 drives, and your virtualization host gains an additional 13.8 tb…

  • Detalhes do produto

That Empty PCIe Slot in Your Server Could Hold 15.36 TB of NVMe Storage. Here Is How.

Every Dell, xFusion, and Lenovo server has at least one PCIe slot that is not being used for a GPU, Placa de rede, or RAID controller. The Supermicro AOC-SLG3-2M2 turns that empty slot into two additional M.2 NVMe drive bays — adding up to 30.72 TB of NVMe storage to any server without consuming a front-panel drive bay, without a U.2 backplane, and without a single SAS cable.

This is the cheapest, simplest path to adding NVMe storage to a server that was not ordered with enough NVMe bays. Populate it with 2x 7.68 TB M.2 22110 drives, and your virtualization host gains an additional 13.8 TB of RAID 1 (ou 15.36 TB JBOD) storage that lives entirely inside the PCIe slot.

Especificações técnicas

Parâmetro Especificação
Modelo Supermicro AOC-SLG3-2M2 (PCIe 3.0 variant)
Host Interface PCIe 3.0 x8 (64 Gb/s — sufficient for 2x NVMe Gen3 drives at ~3.5 GB/s each)
Drive Interface 2x M.2 M-key (NVMe, PCIe 3.0 x4 per slot)
Supported M.2 Form Factors 2242, 2260, 2280, 22110 (adjustable standoffs)
Suporte de ataque No hardware RAID. Raid de software (mdadm, ZFS, Storage Spaces) or VROC (Intel Virtual RAID on CPU) via platform
Bifurcation Required Yes — host PCIe slot must support x4/x4 bifurcation. Most servers from 2020+ support this in BIOS.
Drive Hot-Swap Não compatível (internal card — requires opening chassis to replace drives)
LED Indicators Activity LED per drive (green), fault detection
Power to M.2 Slots 3.3V, supplied via PCIe slot (no supplemental power connector needed)
Fator de forma Low-profile PCIe, full-height bracket included
Physical Dimensions 167 x 69 milímetros (standard LP card)
Resfriamento Passive (requires chassis airflow across M.2 drives)
OS Support VMware ESXi 7.0+, 8.0+ | Servidor Windows 2019/2022/2025 | RHEL 8.6+/9.x | Ubuntu 20.04/22.04/24.04 | TrueNAS Scale | Proxmox VE
Compatible Servers Any server with PCIe 3.0 x8+ slot and x4/x4 bifurcation support
Garantia 3-year limited (manufacturer)

Five Practical Deployments for the AOC-SLG3-2M2

Deployment Unidades Configuration Result
ESXi Boot + Scratch 2x 240 GB M.2 NVMe ATAQUE 1 (software, via ESXi installer) Reliable boot volume, frees 2 front bays for data storage
Hyper-V Storage Spaces 2x 3.84 TB M.2 NVMe Mirror (Storage Spaces) 3.84 TB mirrored VM storage on one PCIe card
TrueNAS SLOG / L2ARC 1x 480 GB M.2 (SLOG) + 1x 1.92 TB M.2 (L2ARC) Dedicated ZFS devices 10x write latency improvement (SLOG), 5x read cache hit rate (L2ARC)
Docker Persistent Volume 2x 7.68 TB M.2 NVMe ATAQUE 1 (mdadm, hardware agnostic) 7.68 TB mirrored container storage in a single PCIe slot
Proxmox Ceph OSD 2x 1.92 TB M.2 NVMe Ceph OSD (bluestore), 1 drive per OSD 2x OSDs per PCIe card — high IOPS density for Ceph clusters

Bifurcation Check — Before You Order

The AOC-SLG3-2M2 requires the host PCIe slot to support x4/x4 bifurcation — splitting the 8 PCIe lanes from the slot into two independent groups of 4 lanes each, one per M.2 drive. Check your server’s BIOS underPCIe Bifurcation” ou “Slot Bifurcationsettings. Most Dell PowerEdge 15th/16th Gen, xFusion V7, and Lenovo V3/V4 servers support this on at least one riser slot. If the BIOS shows “x8” apenas (no bifurcation option), only one M.2 drive will be detected.

On Dell iDRAC9: navigate to Configuration > BIOS Settings > Integrated Devices > Slot Bifurcation. On xFusion iBMC: navigate to BIOS > Advanced > PCI Subsystem > Slot Bifurcation.

Source Through Xincuan

We supply AOC-SLG3-2M2 adapters pre-installed in server configurations with M.2 drives populated. Factory-direct pricing, 3-ano de garantia, and global shipping.

Request an M.2 adapter configured server quote

Anterior:

Deixe uma resposta

Telefone +86 18001060290

LinkedIn LinkedIn

Skype +86 18001060290

Whatsapp +86 18001060290

Código QR do WeChat WeChat

E-mail admin@sell-server.com

WeChat

WeChat QR Code

Escaneie o código QR com o WeChat