APC Smart-UPS SRT 3000VA | Double-Conversion Rack UPS

Your Server Just Rebooted at 3:14 AM Because a Utility Truck Hit a Power Pole Three Blocks AwayThe UPS battery was five years old. The self-test passed last month. The self-test does not simulate a 400ms utility voltage sag while the server is drawing 800W at peak load. When the sag hit, the UPS switched to battery in 4ms — fast enough for the server's power supply capacitors to bridge the gap — but the battery voltage drooped below the inverter threshold before the transfer completed, and the server lost power mid-transaction. The APC Smart-UPS SRT 3000VA is the UPS that survives that scenario: double-conversion topology means the inverter is always powering the load from the battery, not switching from

  • 製品詳細

Your Server Just Rebooted at 3:14 AM Because a Utility Truck Hit a Power Pole Three Blocks Away

The UPS battery was five years old. The self-test passed last month. The self-test does not simulate a 400ms utility voltage sag while the server is drawing 800W at peak load. When the sag hit, the UPS switched to battery in 4ms — fast enough for the server’s power supply capacitors to bridge the gap — but the battery voltage drooped below the inverter threshold before the transfer completed, and the server lost power mid-transaction. The APC Smart-UPS SRT 3000VA is the UPS that survives that scenario: double-conversion topology means the inverter is always powering the load from the battery, not switching from utility to battery when a disturbance is detected. There is no transfer time. There is no gap. The server never sees the utility power disturbance.

技術仕様

パラメータ 仕様
モデル APC Smart-UPS SRT 3000VA RM (SRT3000RMXLT or equivalent)
Topology Double-conversion (online), pure sine wave output always
Output Power Capacity 3,000 VA / 2,700 W
Input Voltage Range 100-275 VAC (auto-sensing, no manual range selection)
Output Voltage 120V or 208V or 230V (configurable), pure sine wave, <2% THD
頻度 50/60 Hz auto-sensing, 0.1 Hz tracking accuracy
Transfer Time 0 ms (online double-conversion — inverter always driving output)
Runtime (Full Load, 2,700W) ~5 minutes (internal battery). まで 60 minutes with external battery pack (SRT192RMBP).
Runtime (Half Load, 1,350W) ~14 minutes (内部). まで 2 hours with external battery pack.
Recharge Time < 3 hours to 90 percent (internal battery)
Battery Type Maintenance-free sealed lead-acid (VRLA), hot-swappable, user-replaceable
Battery Life (典型的な, 25c) 3-5 年
External Battery Pack Support Up to 10x SRT192RMBP external packs (extends runtime proportionally)
Surge Protection 480 Joules, UL 1449 3rd Edition
Outlets 6x NEMA 5-20R (battery backup + surge), 2x additional surge-only
Network Management AP9631 Network Management Card 2 (pre-installed): HTTP/HTTPS, SNMP v1/v2/v3, SSH, Telnet, Modbus TCP, BACnet/IP
Environmental Monitoring AP9335TH temperature/humidity sensor port (sensor sold separately)
Out-of-Band Management Dry contact I/O: UPS on-battery, low-battery, bypass active, remote shutdown, remote reboot
Audible Alarm On-battery, low-battery, overload, replace battery (configurable mute)
Efficiency (Online Mode) >93 percent at 50-100 percent load
Efficiency (Green Mode) >97 percent (bypasses double-conversion when utility power is clean)
フォームファクタ 2U rack-mount (rails included), also supports tower configuration
物理的な 432 バツ 85 バツ 575 んん (2う), 28.6 kg (internal battery)
温度 0C to 40C
Compatible Servers Any server with 120V/208V/230V power supply. Supports Dell, xFusion, レノボ, HPE
保証 3-年 (electronics), 2-年 (battery). Extended warranty available.

Line-Interactive vs Double-Conversion — The Difference That 0 ms Transfer Time Makes

Scenario Line-Interactive UPS (Smart-UPS 1500) Double-Conversion UPS (SRT 3000VA)
Utility voltage sag (brownout) AVR (Automatic Voltage Regulation) adjusts. 2-4 ms transfer to battery if out of AVR range. Inverter always driving load. Output voltage never fluctuates.
Utility power loss 4-8 ms transfer to battery. Server PSU capacitors bridge the gap. 0 ms transfer. Server never sees the interruption.
Generator power (unstable frequency) May not transfer to battery if voltage is within AVR range but frequency is unstable. Inverter regenerates clean 50/60 Hz regardless of input frequency. Generator compatibility: high.
Harmonic distortion on utility power Passes through to load. Depends on server PSU filtering. Inverter output < 2% THD — clean sine wave regardless of input.
Best for Workstations, 角, non-critical infrastructure サーバー, ストレージアレイ, network switches — anything that cannot tolerate a reboot

新川経由のソース

We supply APC Smart-UPS SRT units with factory-direct pricing, 3-年保証, そして世界的な発送. Our engineers can help size the UPS for your server rack power budget and specify external battery packs for your target runtime.

Request a UPS sizing consultation and quote

前へ:

次:

返信を残す

電話 +86 18001060290

リンクトイン リンクトイン

スカイプ +86 18001060290

ワッツアップ +86 18001060290

微信QRコード 微信

Eメール admin@sell-server.com

微信

WeChat QR Code

WeChatでQRコードをスキャン