Notizie dall'azienda

 

How to Design a Tiered Enterprise Storage Architecture: Nvme, SAS SSD, and SAS HDD Reference Design

The Storage Architecture That Saves $70,000 per Rack Without Sacrificing Performance

An all-NVMe storage array delivering 100 TB of usable capacity costs roughly $50,000 in drives alone. A tiered architecture delivering the same 100 TB costs roughly $18,000 in drives while delivering 85-90 percent of the performance for 95 percent of workloads. Across a five-rack deployment, that is $180,000 in total savings.

The Three Tiers

Tier Tipo di unità Example Model Quantità Usable Capacity Cost (Drives Only)
Tier 0: Cache PCIe NVMe 4.0, 3 DWPD, 3.84tubercolosi Samsung PM9A3 3.84TB 4 (RAID 10) 7.68 tubercolosi $2,800
Tier 1: Active Data SAS SSD 12Gb/s, 3 DWPD, 3.84tubercolosi Kingston DC1500M 3.84TB 8 (RAID 10) 15.36 tubercolosi $5,600
Tier 2: Bulk Capacity SAS HDD 12Gb/s, 20tubercolosi Toshiba MG10 20TB 12 (RAID 6) 160 TB usable $4,800
Total 24 azionamenti 183 TB usable $13,200

Automated vs Manual Storage Tiering

Approach A: Automated Tiering (ZFS, Storage Spaces, vSAN). ZFS with a Special Allocation Class on NVMe, a primary pool on SAS SSDs, and a secondary pool on SAS HDDs. Hot blocks migrate to the fastest tier automatically based on access frequency. No manual management required.

Approach B: Manual Classification. The DBA places the database WAL on NVMe (Tier 0), data files on SAS SSD (Tier 1), and backups on SAS HDD (Tier 2). Better performance predictability, but requires ongoing manual management.

Server Configuration: A Tiered Storage Node

Componente Selection Reason
server Dell R760 (2U, 24x 2,5 pollici) Sufficient bays for all three tiers
Alternative (higher density) xFusion2288H V7 (25x 2,5 pollici, 28 Nvme) More NVMe bays for larger Tier 0 cache
processore 2x Xeon Gold 6448Y (32 core) Filesystem operations. No GPU needed.
Memoria 256 GB (16X 16 GB DDR5, 1DPC) ZFS ARC: 128 GB for metadata and hot block caching
RAID/HBA MINUTO H965i (16-porta Gen5 trimodale) Single controller for NVMe, SAS SSD, and SAS HDD
Rete 2x 25GbE SFP28 (front-end), 2x 100GbE (back-end) 25GbE for client access, 100GbE for replication
sistema operativo TrueNAS Scale or RHEL 9 with ZFS ZFS for tiering. TrueNAS for appliance experience.

Performance Estimates: 183 TB Tiered Storage

Workload Expected Performance vs All-NVMe
4K Random Read (Tier 0 cache) ~850K IOPS, 80 us latency 92 percent of all-NVMe
4K Random Read (Tier 1 active data) ~95K IOPS, 120 us latency Consistent SAS SSD performance
4K Random Read (Tier 2 Dati freddi) ~150 IOPS, 4ms latency Sequential prefetch mitigates random penalty
Scrittura sequenziale (to NVMe cache) ~3.5 GB/s (4x NVMe RAID 10) Writes on NVMe, async destage to slower tiers

Three Deployment Scenarios

1. Archivio dati VMware (50 VMs, mixed workloads). NVMe cache absorbs 80 percent of reads. SAS SSD handles active VMDKs. SAS HDD stores snapshots and templates. VMware admins experience NVMe-like latency with 60 percent lower storage cost.

2. PostgreSQL Database (2 tubercolosi, write-heavy OLTP). WAL on NVMe (Tier 0, mirrored). Data files on SAS SSD (RAID 10). Backups on SAS HDD (RAID 6). WAL writes at 2 GB/s sustained, data reads at 95K IOPS.

3. Media Post-Production NAS (50 TB active, 150 TB archive). Current projects on SAS SSD. Completed archives on SAS HDD. NVMe cache for metadata and small-file I/O.

Design Your Tiered Storage With Xincuan

We supply all three storage tiers with factory-direct pricing, 3-anno di garanzia, e spedizioni globali. Our storage architects can design a tiered deployment for your workload.