That Empty PCIe Slot in Your Server Could Hold 15.36 TB of NVMe Storage. Here Is How.
Every Dell, xFusion, and Lenovo server has at least one PCIe slot that is not being used for a GPU, сетевая карта, or RAID controller. The Supermicro AOC-SLG3-2M2 turns that empty slot into two additional M.2 NVMe drive bays — adding up to 30.72 TB of NVMe storage to any server without consuming a front-panel drive bay, without a U.2 backplane, and without a single SAS cable.
This is the cheapest, simplest path to adding NVMe storage to a server that was not ordered with enough NVMe bays. Populate it with 2x 7.68 TB M.2 22110 диски, and your virtualization host gains an additional 13.8 TB of RAID 1 (или 15.36 TB JBOD) storage that lives entirely inside the PCIe slot.
Технические характеристики
| Параметр | Спецификация |
|---|---|
| Модель | Supermicro AOC-SLG3-2M2 (PCIe 3.0 variant) |
| Хост-интерфейс | PCIe 3.0 х8 (64 Gb/s — sufficient for 2x NVMe Gen3 drives at ~3.5 GB/s each) |
| Интерфейс привода | 2x M.2 M-key (NVMe, PCIe 3.0 x4 per slot) |
| Supported M.2 Form Factors | 2242, 2260, 2280, 22110 (adjustable standoffs) |
| Поддержка RAID | No hardware RAID. Программный RAID (mdadm, ZFS, Storage Spaces) or VROC (Intel Virtual RAID on CPU) via platform |
| Bifurcation Required | Yes — host PCIe slot must support x4/x4 bifurcation. Most servers from 2020+ support this in BIOS. |
| Drive Hot-Swap | Not supported (internal card — requires opening chassis to replace drives) |
| LED Indicators | Activity LED per drive (green), fault detection |
| Power to M.2 Slots | 3.3В, supplied via PCIe slot (no supplemental power connector needed) |
| Фактор формы | Low-profile PCIe, full-height bracket included |
| Physical Dimensions | 167 Икс 69 мм (standard LP card) |
| Охлаждение | Passive (requires chassis airflow across M.2 drives) |
| Поддержка ОС | VMware ESXi 7.0+, 8.0+ | Windows Server 2019/2022/2025 | RHEL 8.6+/9.x | Убунту 20.04/22.04/24.04 | TrueNAS Scale | Proxmox VE |
| Compatible Servers | Any server with PCIe 3.0 x8+ slot and x4/x4 bifurcation support |
| Гарантия | 3-year limited (manufacturer) |
Five Practical Deployments for the AOC-SLG3-2M2
| Deployment | Диски | Configuration | Result |
|---|---|---|---|
| ESXi Boot + Scratch | 2Икс 240 GB M.2 NVMe | RAID 1 (software, via ESXi installer) | Reliable boot volume, frees 2 front bays for data storage |
| Hyper-V Storage Spaces | 2Икс 3.84 TB M.2 NVMe | Mirror (Storage Spaces) | 3.84 TB mirrored VM storage on one PCIe card |
| TrueNAS SLOG / L2ARC | 1Икс 480 GB M.2 (SLOG) + 1Икс 1.92 TB M.2 (L2ARC) | Dedicated ZFS devices | 10x write latency improvement (SLOG), 5x read cache hit rate (L2ARC) |
| Docker Persistent Volume | 2Икс 7.68 TB M.2 NVMe | RAID 1 (mdadm, hardware agnostic) | 7.68 TB mirrored container storage in a single PCIe slot |
| Proxmox Ceph OSD | 2Икс 1.92 TB M.2 NVMe | Ceph OSD (bluestore), 1 drive per OSD | 2x OSDs per PCIe card — high IOPS density for Ceph clusters |
Bifurcation Check — Before You Order
The AOC-SLG3-2M2 requires the host PCIe slot to support x4/x4 bifurcation — splitting the 8 PCIe lanes from the slot into two independent groups of 4 lanes each, one per M.2 drive. Check your server’s BIOS under «PCIe Bifurcation» или «Slot Bifurcation» settings. Most Dell PowerEdge 15th/16th Gen, xFusion V7, and Lenovo V3/V4 servers support this on at least one riser slot. If the BIOS shows «х8» только (no bifurcation option), only one M.2 drive will be detected.
On Dell iDRAC9: navigate to Configuration > BIOS Settings > Integrated Devices > Slot Bifurcation. On xFusion iBMC: navigate to BIOS > Advanced > PCI Subsystem > Slot Bifurcation.
Source Through Xincuan
We supply AOC-SLG3-2M2 adapters pre-installed in server configurations with M.2 drives populated. Factory-direct pricing, 3-год гарантии, and global shipping.
Синькуань Сервер | Поставщик оборудования для корпоративных серверов











