MD2412
|
MD2424
|
||
|
رف
|
2يو
|
2يو
|
4يو
|
|
حملة الخلجان
|
12 x 3.5” (14G/15G/16G)
|
24 x 2.5” (14G/15G/16G)
|
60 x 3.5” (Chassis specific)
|
|
الأعلى. drive count
|
يصل إلى 96 for HBA355e يصل إلى 48 for H840 PERC
يصل إلى 96 for HBA355e
|
يصل إلى 96 for HBA355e يصل إلى 96 for H840 PERC Up to 96 for HBA355e
|
يصل إلى 120 for HBA355e يصل إلى 120 for H840 PERC
يصل إلى 120 for HBA355e
|
|
PERC support
|
Yes
|
Yes
|
Yes
|
|
الأعلى. enclosures
|
8 (with HBA355e) 4 (with H840 PERC)
8 (with HBA355e)
|
4 (with HBA355e) 4 (with H840 PERC)
4 (with HBA355e)
|
2 (with HBA355e) 2 (with H840 PERC)
2 (with HBA355e)
|
|
Max capacity
|
1.92PB (20TB HDD)
|
230.40تيرابايت (2.4TB 10K) 737.28تيرابايت (7.68TB SSD)
|
2.40PB (20TB HDD)
|
|
Storage media
|
7.2K SAS/FIPS 3.5” drives − 20TB; 16تيرابايت; 12تيرابايت; 8تيرابايت; 4TB − FIPS: 8تيرابايت
|
10K SAS/FIPS 2.5” drives − 2.4TB; 1.2تيرابايت; 600GB − FIPS: 2.4تيرابايت, 1.2TB SAS SSD/FIPS 2.5” (mixed use) − 1.6TB; 800GB − FIPS: 3.84تيرابايت;
1.92تيرابايت, 960GB SAS SSD/FIPS 2.5” (Read Intensive) − 7.68TB; 3.84تيرابايت; 1.92TB − FIPS: 7.68تيرابايت; 3.84تيرابايت; 1.92تيرابايت |
7.2K SAS/FIPS 3.5” drives − 20TB; 16تيرابايت; 12تيرابايت; 8تيرابايت; 4TB − FIPS: 8تيرابايت
|
|
Host interface
|
12Gb/24Gb SAS
|
12Gb/24Gb SAS
|
12Gb/24Gb SAS
|
|
I/O & الموانئ
|
2x 4-lane 24Gbps SAS host connect per EMM (MD2412, MD2424) 4x 4-lane 24Gbps SAS host connect per EMM (MD2460) 1x USB-C debug ports
per EMM |
2x 4-lane 24Gbps SAS host connect per EMM (MD2412, MD2424) 4x 4-lane 24Gbps SAS host connect per EMM (MD2460) 1x USB-C debug ports
per EMM |
2x 4-lane 24Gbps SAS host connect per EMM (MD2412, MD2424) 4x 4-lane 24Gbps SAS host connect per EMM (MD2460) 1x USB-C debug ports
per EMM |
|
Expansion protocol
|
24Gb SAS4
|
24Gb SAS43
|
24Gb SAS4
|
|
Supported
|
All-Flash, Hybrid Flash (10K HDD only (MD2424); 7.2K HDD only (MD2412, MD2460)
|
All-Flash, Hybrid Flash (10K HDD only (MD2424); 7.2K HDD only (MD2412, MD2460)
|
All-Flash, Hybrid Flash (10K HDD only (MD2424); 7.2K HDD only (MD2412, MD2460)
|
|
إدارة
|
Enclosure Management Modules (EMM) 2 HA EMM per enclosure provide redundant enclosure management capability with iDRAC or SHMCLI
|
Enclosure Management Modules (EMM) 2 HA EMM per enclosure provide redundant enclosure management capability with iDRAC or SHMCLI
|
Enclosure Management Modules (EMM) 2 HA EMM per enclosure provide redundant enclosure management capability with iDRAC or SHMCLI
|
|
PowerEdge servers
|
14G/15G servers; R760, R660, R7625, R6625, R7615, R6615 servers
|
14G/15G servers; R760, R660, R7625, R6625, R7615, R6615 servers
|
14G/15G servers; R760, R660, R7625, R6625, R7615, R6615 servers
|
|
Wattage
|
800دبليو
|
800دبليو
|
1500دبليو
|
|
Voltage
|
MD2412: 100-127/200-240 بطالة; 240 VDC (China only)
|
MD2424: 100-127/200-240 بطالة; 240 VDC (China only)
|
MD2460: 200-240 بطالة; 240 VDC (China only)
|
|
Frequency
|
50/60 هرتز
|
50/60 هرتز
|
50/60 هرتز
|
Original Brand New Dells PowerVault MD2412 MD2424 MD2460 Direct-Attached Storage DAS JBOD Enclosures Storage Server