% % %

Новости компании

 

How to Design a Tiered Enterprise Storage Architecture: NVMe, SSD-накопитель SAS, and SAS HDD Reference Design

The Storage Architecture That Saves $70,000 per Rack Without Sacrificing Performance

An all-NVMe storage array delivering 100 TB of usable capacity costs roughly $50,000 in drives alone. A tiered architecture delivering the same 100 TB costs roughly $18,000 in drives while delivering 85-90 percent of the performance for 95 percent of workloads. Across a five-rack deployment, that is $180,000 in total savings.

The Three Tiers

Tier Тип привода Example Model Количество Usable Capacity Cost (Drives Only)
Tier 0: Кэш NVMe PCIe 4.0, 3 ДВПД, 3.84ТБ Samsung PM9A3 3.84TB 4 (RAID 10) 7.68 ТБ $2,800
Tier 1: Active Data SAS SSD 12Gb/s, 3 ДВПД, 3.84ТБ Kingston DC1500M 3.84TB 8 (RAID 10) 15.36 ТБ $5,600
Tier 2: Bulk Capacity SAS HDD 12Gb/s, 20ТБ Тошиба МГ10 20 ТБ 12 (RAID 6) 160 TB usable $4,800
Total 24 диски 183 TB usable $13,200

Automated vs Manual Storage Tiering

Approach A: Automated Tiering (ZFS, Storage Spaces, vSAN). ZFS with a Special Allocation Class on NVMe, a primary pool on SAS SSDs, and a secondary pool on SAS HDDs. Hot blocks migrate to the fastest tier automatically based on access frequency. No manual management required.

Approach B: Manual Classification. The DBA places the database WAL on NVMe (Tier 0), data files on SAS SSD (Tier 1), and backups on SAS HDD (Tier 2). Better performance predictability, but requires ongoing manual management.

Server Configuration: A Tiered Storage Node

Компонент Selection Reason
Сервер Dell R760 (2U, 24х 2,5 дюйма) Sufficient bays for all three tiers
Alternative (higher density) xFusion 2288H V7 (25х 2,5 дюйма, 28 NVMe) More NVMe bays for larger Tier 0 кеш
Процессор 2x Xeon Gold 6448Y (32 ядра) Filesystem operations. No GPU needed.
Память 256 ГБ (16Икс 16 GB DDR5, 1ЦОД) ZFS ARC: 128 GB for metadata and hot block caching
RAID/HBA МИНУТА H965i (16-port Gen5 tri-mode) Single controller for NVMe, SSD-накопитель SAS, and SAS HDD
сеть 2x 25GbE SFP28 (front-end), 2x 100GbE (back-end) 25GbE for client access, 100GbE for replication
ОС TrueNAS Scale or RHEL 9 with ZFS ZFS for tiering. TrueNAS for appliance experience.

Performance Estimates: 183 TB Tiered Storage

Рабочая нагрузка Expected Performance vs All-NVMe
4K Random Read (Tier 0 кеш) ~850K IOPS, 80 us latency 92 percent of all-NVMe
4K Random Read (Tier 1 active data) ~95K IOPS, 120 us latency Consistent SAS SSD performance
4K Random Read (Tier 2 холодные данные) ~150 IOPS, 4ms latency Sequential prefetch mitigates random penalty
Последовательная запись (to NVMe cache) ~3.5 GB/s (4x NVMe RAID 10) Writes on NVMe, async destage to slower tiers

Three Deployment Scenarios

1. VMware Datastore (50 Виртуальные машины, mixed workloads). NVMe cache absorbs 80 percent of reads. SAS SSD handles active VMDKs. SAS HDD stores snapshots and templates. VMware admins experience NVMe-like latency with 60 percent lower storage cost.

2. PostgreSQL Database (2 ТБ, write-heavy OLTP). WAL on NVMe (Tier 0, зеркальный). Data files on SAS SSD (RAID 10). Backups on SAS HDD (RAID 6). WAL writes at 2 GB/s sustained, data reads at 95K IOPS.

3. Media Post-Production NAS (50 TB active, 150 TB archive). Current projects on SAS SSD. Completed archives on SAS HDD. NVMe cache for metadata and small-file I/O.

Design Your Tiered Storage With Xincuan

We supply all three storage tiers with factory-direct pricing, 3-год гарантии, and global shipping. Our storage architects can design a tiered deployment for your workload.

Request a tiered storage design consultation

Storage products: SSD | жесткие диски | Storage Solutions

Пред.:

Телефон +86 18001060290

LinkedIn LinkedIn

Скайп +86 18001060290

WhatsApp +86 18001060290

QR-код WeChat WeChat

Электронная почта admin@sell-server.com

WeChat

WeChat QR Code

Отсканируйте QR-код с помощью WeChat