| PowerVault MD Series | |||
| MD2412 | MD2424 | MD2460 | |
| Dimensione del rack | 2U | 2U | 4U | 
| Drive bay | 12 x 3.5” (14G/15G/16G) | 24 x 2.5” (14G/15G/16G) | 60 x 3.5” (Chassis specific) | 
| Massimo. drive count for 14G/15G PE servers | Fino a 96 for HBA355e Up to 48 for H840 PERC | Fino a 96 for HBA355e Up to 96 for H840 PERC | Fino a 120 for HBA355e Up to 120 for H840 PERC | 
| Massimo. drive count for 16G PE servers | Fino a 96 for HBA355e | Fino a 96 for HBA355e | Fino a 120 for HBA355e | 
| PERC support1 | SÌ | SÌ | SÌ | 
| Massimo. enclosures for 14G/15G PE servers | 8 (with HBA355e) 4 (with H840 PERC) | 4 (with HBA355e) 4 (with H840 PERC) | 2 (with HBA355e) 2 (with H840 PERC) | 
| Massimo. enclosures for 16G PE servers | 8 (with HBA355e) | 4 (with HBA355e) | 2 (with HBA355e) | 
| Max capacity2 | 1.92PB (20TB HDD) | 230.40tubercolosi (2.4TB 10K) 737.28tubercolosi (7.68TB SSD) | 2.40PB (20TB HDD) | 
| 10K SAS/FIPS 2.5” drives – 2.4tubercolosi; 1.2tubercolosi; 600GB – FIPS: 2.4tubercolosi, 1.2tubercolosi | |||
| Media di archiviazione | 7.2K SAS/FIPS 3.5” drives – 20tubercolosi; 16tubercolosi; 12tubercolosi; 8tubercolosi; 4tubercolosi – FIPS: 8tubercolosi | SAS SSD/FIPS 2.5” (mixed use) – 1.6tubercolosi; 800GB – FIPS: 3.84tubercolosi; 1.92tubercolosi, 960GB | 7.2K SAS/FIPS 3.5” drives – 20tubercolosi; 16tubercolosi; 12tubercolosi; 8tubercolosi; 4tubercolosi – FIPS: 8tubercolosi | 
| SAS SSD/FIPS 2.5” (Leggi intensivo) – 7.68tubercolosi; 3.84tubercolosi; 1.92tubercolosi – FIPS: 7.68tubercolosi; 3.84tubercolosi; 1.92tubercolosi | |||
| Interfaccia host (autosensing) | 12Gb/24Gb SAS | 12Gb/24Gb SAS | 12Gb/24Gb SAS | 
| I/O & Porti | 2x 4-lane 24Gbps SAS host connect per EMM (MD2412, MD2424) 4x 4-lane 24Gbps SAS host connect per EMM (MD2460) 1x USB-C debug ports per EMM | ||
| Expansion protocol | 24Gb SAS4 | 24Gb SAS43 | 24Gb SAS4 | 
| Supportato | All-Flash, Hybrid Flash (10K HDD only (MD2424); 7.2K HDD only (MD2412, MD2460) | ||
| Gestione | Enclosure Management Modules (EMM) 2 HA EMM per enclosure provide redundant enclosure management capability with iDRAC or SHMCLI | ||
| PowerEdge servers4 | 14G/15G servers; R760, R660, R7625, R6625, R7615, R6615 servers | ||
| Sistema di base fisica | |||
| MD2412 | MD2424 | MD2460 | |
| Altezza del sistema di base | 86.8 mm 3.4 pollici | 86.8 mm 3.4 pollici | 174.3 mm 6.86 pollici | 
| Larghezza del sistema di base | 444.0 mm 17.5 pollici | 444.0 mm 17.5 pollici | 423 mm 16.65 pollici | 
| Profondità del sistema di base | 545 mm 21.5 pollici | 497 mm 19.5 pollici | 875 mm 34.45 pollici | 
| Peso (with drives) | 25.58 kg 56.39 libbre | 21.76 kg 49. libbre | 90.70 kg 199.96 libbre | 
| Peso (senza unità) | 15.98 kg 35.23 libbre | 16.0 kg 35.27 libbre | 47.18 kg 104.03 libbre | 
| Wattage | MD2412: 800W MD2424: 800W MD2460: 1500W | |
| Voltaggio | MD2412: 100-127/200-240 Vac; 240 VDC (Solo Cina) MD2424: 100-127/200-240 Vac; 240 VDC (Solo Cina) MD2460: 200-240 Vac; 240 VDC (Solo Cina) | |
| Frequenza | 50/60 Hz | |
 Vendi server Dell/Xfusion/Huawei,Dalla Cina.